OVERVIEW
Applied in the testing and quality control of smart lithium batteries or battery packs such as e-bike, drones, medical equipment, balance-robot, and vacuum cleaner, and can realize the integration of charging and discharging data monitoring.
ADVANTAGES
FUNCTION TEST
specification
| Models | RCDS-60V / 100V | |
|---|---|---|
| AC parameters | Wiring method | Three-phase five-wire system |
| Power supply voltage | 380±10% VAC | |
| Power supply frequency | 50±5% Hz | |
| Power factor | > 0.99 | |
| Max. power feedback efficiency | ≥ 90% | |
| THD | < 5% | |
| DC parameters | Output current | 20A / 30A / 40A / 60A ······· |
| Single channel voltage range | 60V~100V | |
| Voltage accuracy | ± 0.05% F.S | |
| Voltage resolution | 1mV | |
| Current accuracy | ± 0.05% F.S | |
| Current resolution | 1mA | |
| Current start response time | 20ms (10%~90%F.S) | |
| Current switching time | 40ms (~90%~90%F.S) | |
| Software Function | Charging mode | CC, CV, CCCV, CP etc. |
| Discharge mode | CC, CV, CP, CR etc. | |
| Other working mode | Still, Pause | |
| Test cut-off condition | Battery voltage, current, time, capacity, temperature | |
| Data export format | Excel, TXT etc. | |
| Data recording interval | 100ms | |
| Editable step | Max. 10000 | |
| Programmable step | Max. 10000 | |
| Nested loop | Max. 10 layers | |
| Software protection | OCP/OVP/Reverse or wrong connection protection/ Protection for abnormal communication | |
| Third-party device integration | Supports linkage of temperature box, MTV/MTS, and pressure sensor | |
| Other parameters | IP grade | IP20 |
| Working temperature | 0℃~40℃ | |
| Cooling method | Forced Fan-cooled | |
| Noise | < 75dB | |
| Cabinet size (W*D*H mm) | 600*850*1030 / 600*800*1980 | |